In vivo dosimetry in total body irradiation
Main Article Content
Abstract
Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patient’s body and it is characterized by an extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions in TBI. For these reasons, it is highly recommended to use In Vivo Dosimetry (IVD), to guarantee the quality of TBI treatments as a direct measurement of the delivered dose. An IVD QA system was implemented based on semiconductor diodes and radiochromic films. For the commissioning of the system, both detector types were calibrated independently, using as reference an ionization chamber with a valid certificate in terms of absorbed dose to water (Dw). This guarantees the traceability of the measurements. An experiment was carried out to simulate a clinical TBI procedure to a phantom. In this way, the calibration of the dosimetry system was confirmed.
Article Details
How to Cite
Llanes Veiga, E., Alfonso Laguardia, R., & Caballero Pinelo, R. (2019). In vivo dosimetry in total body irradiation. Nucleus, (65), 51-55. Retrieved from http://nucleus.cubaenergia.cu/index.php/nucleus/article/view/680
Section
Ciencias Nucleares
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista. Bajo esta licencia el autor será libre de:
- Compartir — copiar y redistribuir el material en cualquier medio o formato
- Adaptar — remezclar, transformar y crear a partir del material
- El licenciador no puede revocar estas libertades mientras cumpla con los términos de la licencia
Bajo las siguientes condiciones:
- Reconocimiento — Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.
- NoComercial — No puede utilizar el material para una finalidad comercial.
- No hay restricciones adicionales — No puede aplicar términos legales o medidas tecnológicas que legalmente restrinjan realizar aquello que la licencia permite.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).
La Revista Nucleus solo aceptará contribuciones que no hayan sido previamente publicados y/o procesados, por otra publicación. Cualquier violación ese sentido será considerada una falta grave por parte del autor principal lo cual será objeto valoración por parte del Consejo Editorial, el cual dictaminará al respecto.
References
[1] BELTRÁN D. Irradiacion corporal total (TBI). Murcia: Fundación Grupo IMO, 2015.
[2] American Association of Physicists in Medicine by Medical Physics. Diode in vivo dosimetry for patients receiving external beam radiation therapy. AAPM Report No. 087. Report of Task Group 62 of the Radiation Therapy Committee. American Association of Physicists in Medicine by Medical Physics, 2005.
[3] American Association of Physicists in Medicine by Medical Physics. Diode in vivo dosimetry for patients receiving external beam radiation therapy. AAPM Report No. 087. Report of Task Group 62 of the Radiation Therapy Committee. American Association of Physicists in Medicine by Medical Physics, 2005.
[4] RIBAS M, JORNET N, EUDALDO T, CARRASCO P. Aspectos generales de la dosimetría in vivo con diodos. Servei de Radiofisica I Radioproteccio, Hospital Santa Creu I Sant Pau. Barcelona, Spain, 2010.
[5] PTW. Manual de usuario MULTIDOS T10004. 2011.
[6] MOYLAN R, TRENT A, KAIRN T. Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry. Phys Eng Sci Med. 2013; (36): 331-337
[7] VAN DAN J, MARINELLO G. Methods for in vivo dosimetry in external radiotherapy. Brussels: ESTRO, 2006.
[8] PTW. Manual de usuario VivoSoft a partir de la versión 3.0.1. 2010.
[2] American Association of Physicists in Medicine by Medical Physics. Diode in vivo dosimetry for patients receiving external beam radiation therapy. AAPM Report No. 087. Report of Task Group 62 of the Radiation Therapy Committee. American Association of Physicists in Medicine by Medical Physics, 2005.
[3] American Association of Physicists in Medicine by Medical Physics. Diode in vivo dosimetry for patients receiving external beam radiation therapy. AAPM Report No. 087. Report of Task Group 62 of the Radiation Therapy Committee. American Association of Physicists in Medicine by Medical Physics, 2005.
[4] RIBAS M, JORNET N, EUDALDO T, CARRASCO P. Aspectos generales de la dosimetría in vivo con diodos. Servei de Radiofisica I Radioproteccio, Hospital Santa Creu I Sant Pau. Barcelona, Spain, 2010.
[5] PTW. Manual de usuario MULTIDOS T10004. 2011.
[6] MOYLAN R, TRENT A, KAIRN T. Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry. Phys Eng Sci Med. 2013; (36): 331-337
[7] VAN DAN J, MARINELLO G. Methods for in vivo dosimetry in external radiotherapy. Brussels: ESTRO, 2006.
[8] PTW. Manual de usuario VivoSoft a partir de la versión 3.0.1. 2010.