Protocol for the realization of breast scintigraphy with 99mTc-MIBI using a prone decubitus positioning device

Main Article Content

Armando Del Pozo Almaguer
Rodolfo Suárez Iznaga
Adlin López Díaz
Consuelo Varela Corona

Abstract

Breast cancer is the second most frequent neoplasm in the Cuban woman. Image techniques play a fundamental role for the diagnosis, staging and monitoring of the disease. This work had the objective of: Implement the Clinical Protocol for the scintimammography with 99mTc-MIBI for the detection of palpable tumor lesions in dense breasts, difficult mammographic assessment and suspected axillary metastatic lymph nodes employing a craft device of prone decubitus positioning. 35 patients were included with an average age of 51 years, who attended the central consultation of breast pathology at Dr. Salvador Allende Hospital. It was designed and constructed an artisanal device that made it possible to carry out the studies from an anatomical position pendant or pendulum of the breast, demonstrating its usefulness in the medical assessment of the scintimammography images. Of the studies carried out 17.1 % was positive for malignant mammary neoplastic tissue, with a specificity of 100 %. The number of unnecessary biopsies by false positive mammograms or inconclusive in lesions greater than 10 mm in diameter was decreased by 82.9 %. The clinical protocol was implemented for the scintimammography with 99mTc-MIBI for the detection of palpable tumor lesions in dense breasts, difficult mammographic assessment and suspected axillary metastatic lymph nodes employing a craft device of prone decubitus positioning. It proved to be a simple, reproducible and non-invasive test, which can facilitate and improve the diagnosis of breast cancer.

Article Details

How to Cite
Del Pozo Almaguer, A., Suárez Iznaga, R., López Díaz, A., & Varela Corona, C. (1). Protocol for the realization of breast scintigraphy with 99mTc-MIBI using a prone decubitus positioning device. Nucleus, (72), 23-26. Retrieved from http://nucleus.cubaenergia.cu/index.php/nucleus/article/view/769
Section
Ciencias Nucleares

References

[1]. Cuba. Ministerio de Salud Pública (MINSAP). Anuario Estadístico de Salud 2020 [en línea]. Disponible en: www.salud.msp.gob.cu
[2]. HEYDARHEYDARI S, REZAEIJO SM, CHEKI M, et. al. Diagnostic efficacy of technetium-99m-sestamibi scintimammography in comparison with mammography to detect breast lesions: a systematic review. Arch Breast Cancer. 2018; 5(3): 98-105.
[3]. NIKOLAEVICH S, VIKTOROVNA A, IVANOVICH P, et. al. 99mTc-MIBI scintimammography and digital mammography in the diagnosis of multicentric breast cancer. Hell J Nucl Med. 2019; 22(3): 172-178.
[4]. AGUILAR E, CARRERAS JL, MEROÑO E, AGUILAR A. Tecnecio MIBI y patología mamaria. Su utilidad en el diagnóstico. Rev. Senología y Patol. Mam. 1998; 11(4): 191-199.
[5] .FLIQUETE MV, GIMENEZ J, VÁZQUEZ FC, et. al. Papel del 99mTc-Sestamibi en el diagnóstico del cáncer de mama. A propósito de 100 casos. Rev. Esp. Med. Nuclear. 1999; 18(6): 436-441.
[6]. DE LOS REYES A, LLAMAS A. La gammagrafía mamaria con tecnecio-99m sestamibi puede mejorar la capacidad diagnóstica de la mamografía en pacientes con masas palpables. Rev. Col. Cancerología. 2005; 9(1): 12-18.
[7]. GREENE LR, WILKINSON D. The role of general nuclear medicine in breast cancer. J Med Radiat Sci. 2015; (62): 54-65.
[8]. BROSED A, PUCHAL R. Fundamentos de Física Médica. Volumen 6: Medicina Nuclear: bases físicas, equipos y control de calidad. Sociedad Española de Física Médica, 2014.
[9]. CHAIN Y, ILLANES L. Radiofármacos en medicina nuclear: fundamentos y aplicación clínica. Universidad Nacional de La Plata, 2015.
[10]. NOVER AB, JAGTAP S, ANJUM W, et. al. Modern breast cancer detection: a technological review. Int J Biomed Imaging. 2009; 2009: 902326.
[11]. VIEIRA AG, PEREIRA EN, CHOJNIAK R, et. al. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas. Radiol Bras. 2014; 47(2): 67-73.
[12]. GONZÁLEZ DE, INFANTE JR, PAUMIER Y, et. al. Construcción de un dispositivo para el posicionamiento óptimo del paciente en estudios de gammagrafía mamaria. Nucleus. 2016; (59): 5-8.
[13]. GILBERT FJ, HICKMAN SE, BAXTER GC, et. al. Opportunities in cancer imaging: risk-adapted breast imaging in screening. Clinical Radiology. 2021; 76: 763-773.
[14]. VIDAL-SICART S, AUKEMA TS, VOGEL WV, et. al. Valor añadido de la técnica en decúbito prono para el estudio con tomografía por emisión de positrones-tomografía computarizada en las pacientes con cáncer de mama. Rev Esp Med Nucl. 2010; 29(5): 230-235.
[15]. Hospital Docente Clínico Quirúrgico "Dr. Salvador Allende". Informes de estudios gammagráficos del Servicio de Medicina Nuclear, 2017-2020.